NO.
|
parts
|
brand
|
1
|
5.4
touch color screen
|
远智
|
2
|
Self
draining air source filter
|
SMC
|
3
|
Precision
manual pressure regulating valve
|
SMC
|
4
|
Solenoid
valve and electromagnetic valve seat
|
festo
|
5
|
High
precision pressure transmitter
|
Emerson
|
6
|
Inflatable,
balanced valve core
|
Germany
|
7
|
Leaking
connector
|
festo
|
8
|
chip
|
32BIT
core processor
|
技术参数
Display unit
|
Test pressure
|
kPa,Mpa、bar,PSI
|
Leakage
|
Pa,Pa/s,mL/min
|
Mainframe
size
|
312(L)×277(W)×155(H)
|
Resolution accuracy
|
1PaΩ0.1ML/min
|
Minimum display
|
0.1Pa
|
Display range
|
0~±1999.9Pa
|
Precision guarantee range
|
0~±2000Pa
|
Sensor range
|
0~±2000Pa
|
Test pressure range
|
5-300kPa
|
Pressure
resistance of sensor
|
0.6MPa
|
Leakage volume display
|
The number of digits is 3, and
the number of decimal digits is 1.
Display sampling frequency 10HZ
|
Leaking
upper and lower limits
|
Less than 1999.9Pa
|
Parameter channel number
|
32group(0~32)
|
Time setting
|
0~999s
|
Hardware
|
32bitCPU
|
Power Supply
|
AC220V±5%,50HZ
|
Test pressure source
|
In general, dry clean air using 0.2~0.3MPa
higher than the test pressure.
|
ambient temperature
|
The temperature is 5~40 centigrade.
|
The preservation temperature is 0
~ 70 C
|
|
Humidity
|
80%RH, below, no condensation
|
Control the IO interface
|
Open circuit collector specification interface
and relay output
|
Note: the single side height of both sides screws is 2mm
5.4-inch touch screen display, Chinese operation interface is clear and easy to understand;
Check the waveform diagram to facilitate analysis of the inspection process;
Differential pressure resolution, high precision;
Multi-channel parameters, the parameter channel selection and setting can be easily performed;
8 output control, 8 control inputs;
With manual test mode and automatic test mode;
With serial RS232 level output;
The remote control contacts are rich, can be connected to the PLC, and can also directly drive external devices (such as cylinders);
The output terminals can be manually adjusted to make external control more flexible;
The bubble-coating function, that is, when the soapy water is soaked in water to visually detect the bubbles, the instrument maintains a pressure-holding state;
The latest 10000 sets of test data can be saved, and the test results can be queried by date;
Leak detection result data, automatically stored;
Rich in data statistics and analysis functions;
With power-off memory protection
Use U disk to export data function; export data to EXCEL, easy to edit on computer
Direct drive to printer or scanner
Quality analysis: Analyze and classify product quality by analyzing and categorizing the products tested
Leakage calculation: Simple and fast calculation of differential pressure leakage values and flow leakage values to help process and operators quickly calculate leak data.
Low voltage test: DC24V safe voltage